CX2-B0-14-620-22A [Carling Technologies]

CIRCUIT BREAKER;
CX2-B0-14-620-22A
型号: CX2-B0-14-620-22A
厂家: Carling Technologies    Carling Technologies
描述:

CIRCUIT BREAKER

文件: 总12页 (文件大小:1558K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CX  
eries-Series  
CX-S  
CIRCUIT BREAKER  
The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the  
breaker to safely handle high amperage and high DC voltage applications in a compact package. By using a  
patent pending magnetic flux boosting terminal configuration, a strong magnetic field is created thus motivating  
the arc into an enhanced arc chamber improving the breaker’s overall performance and reliability. The permanent  
magnets located at the entrance of the arc chamber combined with the upper and lower arc runner increase  
the magnetic blow out force and aid in motivating the arc off of the contacts and into the arc chamber. An  
enhanced arc chamber features arc splitter retainers with integrated pressurizing walls, which facilitates heat  
transfer from the arc thereby providing additional cooling and quick transition into the magnetically induced  
splitter plates. In turn, the twelve (12) splitter plates attract, segment and cool the arc for full extinction  
Combined, these innovative features make the CX-Series breaker the best in class, providing stable performance  
even in the most demanding applications.  
Resources:  
Download 3D CAD Files  
IGS  
STP  
Watch Product Video  
Product Highlights:  
UL 489 & UL 489B Listed  
Typical Applications:  
Renewable Energy  
Š
Š
Š
Š
TUV Certified IEC/EN 60947-2  
Power Distribution Units  
Š
Temperature stable hydraulic-magnetic  
overcurrent sensing technology  
Š
Optional relay trip circuit permitting remote  
operator system shut down  
Š
Perfect fit for 380VDC Applications  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Email: sales@carlingtech.com  
Application Support: team2@carlingtech.com  
Phone: 860.793.9281 Fax: 860.793.9231  
www.carlingtech.com  
|
CX-Series Circuit Breaker - Design Features  
2
CX-Series  
DESIGN FEATURES  
HYDRAULIC/MAGNETIC  
SENSING COIL  
UPPER ARC RUNNER  
Aids in motivating arc off of movable  
contact and into arc chamber  
MAGNETS  
ARC SPLITTER  
RETAINER  
with integrated  
pressurizing walls  
PATENT PENDING MAGNETIC FLUX  
BOOSTING TERMINAL CONFIGURATION  
Design enhances motivation  
(12) ARC DEIONIZING  
SPLITTER PLATES  
LOWER ARC RUNNER  
LARGE ARC GAP  
To generate high  
arc voltages  
Aids in motivating arc  
off of stationary contact  
and into arc chamber  
of arc into arc chamber  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
CX-Series Circuit Breaker - General Specifications  
|
3
Electrical Tables  
Table A: Lists UL Listed (UL489) configuration and performance capabilities as a Molded Case Circuit Breaker  
CX SERIES TABLE A : UL489 LISTED BRANCH CIRCUIT BREAKERS  
VOLTAGE  
CIRCUIT  
MAX CURRENT INTERRUPTING  
NUMBER  
CONFIGURATION  
RATING AMPS CAPACITY (AMPS) OF POLES  
MAX. RATING FREQUENCY  
1
2
2
250  
D.C.  
D.C.  
D.C.  
15  
15  
50  
5,000  
10,000  
10,000  
250 / 500  
410 / 205  
SERIES  
Table B: Lists UL Recognized configurations and performance capabilities as a Component Supplementary Protector  
CX SERIES TABLE B : UL1077 COMPONENT SUPPLEMENTARY PROTECTOR  
VOLTAGE  
MAX  
CURRENT  
RATING AMPS  
INTERRUPTING  
CAPACITY  
(AMPS)  
CIRCUIT  
CONFIGURATION  
NUMBER APPLICATION  
OF POLES  
CODE  
MAX.  
RATING  
FREQUENCY  
300  
300  
440  
440  
600  
600  
D.C.  
D.C.  
D.C.  
D.C.  
D.C.  
D.C.  
1 - 75  
76 - 125  
1 -30  
5,000  
3,000  
10,000  
5,000  
5,000  
3,000  
1
1
2
2
2
2
TC1, OL0, U3  
TC1, OL0, U3  
TC1, OL0, U3  
TC1, OL0, U3  
TC1, OL0, U3  
TC1, OL0, U3  
SERIES  
31 - 63  
1 - 75  
76 - 115  
SWITCH ONLY1  
600  
D.C.  
1 - 115  
----  
2 or 3  
---  
Notes:  
1
Requires inclusion of a relay trip voltage coil  
Table C: Lists UL Listed (UL489B) configuration and performance capabilities as a Molded Case Switch  
CX SERIES TABLE C : UL489B LISTED PHOTOVATIC MOLDED CASE SWITCH  
VOLTAGE  
CIRCUIT  
CURRENT RATING INTERRUPTING  
CONSTRUCTION  
NOTES  
CONFIGURATION MAX RATING FREQUENCY POLES  
(AMPS)  
RATING (AMPS)  
May have a third pole  
that is a voltage  
trip pole  
600  
600  
DC  
DC  
21  
42  
50 - 100  
600  
SERIES  
May have a fifth pole  
that is a voltage  
trip pole  
110 - 175  
600  
Notes:  
1
2
Two poles in series.  
Two poles in series in parallel with 2 poles in series.  
Table D: TUV Certified Configuration to IEC / EN 60947-2. Low Voltage Switch gear and Control gear - Circuit Breakers  
CX-SERIES TABLE D : TUV IEC/EN 60947-2 LOW VOLTAGE SWITCH GEAR &  
CONTROL GEAR / CIRCUIT BREAKER  
INTERRUPTING  
CAPACITY  
VOLTAGE  
CIRCUIT  
CURRENT RATING  
(AMPS)  
CONFIGURATION  
MAX.  
ICS / ICU  
(AMPS)  
FREQUENCY  
DC  
ꢀꢁꢂꢃꢄ  
RATING  
SERIES  
440  
1-63  
4,000  
*Manufacturer reserves the right to change product specification without prior notice.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
4
CX-Series Circuit Breaker - General Specifications  
Electrical  
Mechanical  
Maximum Voltage  
Overload  
600 VDC  
Endurance  
Max 10,000 ON-OFF operations @  
6 per minute; 6000 with rated  
current & voltage, and 4,000 cycles  
mechanical.  
50 operations at 600% of rated  
current for UL489, and at 150% of  
rated current for UL1077.  
Trip Free  
Trips on overload even when  
actuator is forcibly held in the “On”  
position.  
The operating handle moves  
positively to the “Off” position when  
an overload causes the breaker  
to trip.  
RESISTANCEPERPOLEVALUES  
from Line to Load Terminals  
(Values Based on Series Trip Circuit Breaker)  
1000  
100  
10  
CURRENT  
(AMPS)  
TOLERANCE  
(%)  
Trip Indication  
0.10 - 5.0  
5.1 - 20.0  
20.1 - 50.0  
15  
25  
35  
O
H
M
S
1
Environmental  
Shock  
Withstands 100 Gs, 6ms saw tooth  
while carrying rated current per  
MILPRF-55629 and MIL-STD-  
202G, Method 213G, Test Condition  
“I”. Instantaneous and ultra short  
curves tested at 90% of rated current  
Withstands 0.060” excursion  
from 10-55 Hz & 10 Gs 55-500 Hz,  
at rated current per MIL-PRF-55629  
and MILSTD-202G, Method 240D,  
Test Cond. A. Instantaneous &  
ultrashort curves tested at 90% of  
rated current.  
MIL-PRF-55629 and MIL-STD-  
202G, Method 106G, i.e., Ten 24-  
hour cycles at +25°C to +65°C, 80-  
98% RH.  
Method 101, Condition A (90-95%  
RH at 5% NaCl Solution, 96 hrs).  
MIL-PRF-55629 and MIL-STD-  
202G, Method 107G, Condition A  
(5-cycles at -55°C to +25°C to  
+85°C to +25°C).  
0.1  
0.01  
0.001  
0.01  
0.1  
1
10  
100-110205  
AMPERE RATING  
Vibration  
Physical  
Number of Poles  
Termination  
1- 2 poles, + Auxiliary Switch Pole.  
10-32 or M5 Screw Terminals  
1/4-20 or M6 Threaded Stud  
Terminals  
Termination Barrier  
Mounting  
Standard with multi-pole constructions  
Threaded insert: #6-32 UNC-2B, or  
M3X0.5-6H B ISO (2 per pole)  
Handle, 1 per pole.  
Moisture Resistance  
Actuator  
Internal Circuit Config.  
Materials  
Series Trip  
Salt Spray  
Housing - Glass filled Polyester  
Handle - Glass filled Polyester  
Line/Load Terminals - Copper Alloy.  
~150 Grams (~5.3 Ounces).  
~150 Grams (~5.3 Ounces).  
Housing - Gray.  
Thermal Shock  
Weight  
Standard Color  
Operating Temperature  
-40°C to +85°C.  
Handle - White, Black, Red, Green,  
Blue, Yellow, Gray,  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
CX-Series Circuit Breaker - UL489 – Ordering Scheme |  
5
C X 1 B 0 14 615 2 2 A 12 G  
8
9
10  
Mounting  
Inserts  
11  
Rating  
12  
Agency  
Approval  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color &  
Legend  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
1 SERIES  
C
8 TERMINAL  
2
3
5
6
Screw Terminal, 10-32  
Stud, 1/4-20  
Screw Terminal, M5  
Stud, M6  
2 ACTUATOR  
Handle, one per pole  
X
9 ACTUATOR COLOR & LEGEND  
3 POLES  
Actuator Color  
White  
Black  
I-O  
A
C
F
ON-OFF  
Dual  
Legend Color  
Black  
White  
White  
White  
White  
Black  
Black  
Black  
1
2
One  
Two  
B
D
G
J
1
2
3
4
5
6
7
8
Red  
Green  
Blue  
Yellow  
Gray  
H
K
M
P
4 CIRCUIT  
Series Trip current  
L
(
)
B
N
Q
S
5 AUXILIARY/ALARM SWITCH  
Without Aux Switch  
Orange  
R
0
10 MOUNTING INSERTS  
6 FREQUENCY & DELAY  
A
B
6-32 Thread  
M3 Thread  
11  
12  
14  
16  
DC Ultra Short  
DC Short  
DC Medium  
DC Long  
11 MAX. APPLICATION RATING  
12 250 VDC  
13 250/500 VDC  
1
7 CURRENT RATING (AMPERES)  
CODE AMPERES  
15 205/410 VDC  
220 0.20  
225 0.25  
230 0.30  
235 0.35  
240 0.40  
245 0.45  
250 0.50  
255 0.55  
260 0.60  
265 0.65  
270 0.70  
275 0.75  
280 0.80  
285 0.85  
290 0.90  
295 0.95  
410 1.00  
512 1.25  
415 1.50  
517 1.75  
420 2.00  
522 2.25  
425 2.50  
527 2.75  
430 3.00  
435 3.50  
440 4.00  
445 4.50  
450 5.00  
455 5.50  
460 6.00  
614 14.00  
615 15.00  
616 16.00  
617 17.00  
618 18.00  
620 20.00  
622 22.00  
624 24.00  
625 25.00  
630 30.00  
635 35.00  
640 40.00  
645 45.00  
650 50.00  
465 6.50  
470 7.00  
475 7.50  
480 8.00  
485 8.50  
490 9.00  
495 9.50  
610 10.00  
710 10.50  
611 11.00  
711 11.50  
612 12.00  
712 12.50  
613 13.00  
12 AGENCY APPROVAL  
A
G
S
Without Approvals  
UL 489 Listed  
UL 489 Listed, TUV to IEC60947-2  
1
Notes:  
1
Only Available with 250/500 VDC up to 15 amps.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
6
CX-Series Circuit Breaker - UL489B – Ordering Scheme  
C X 2 S 0 03 810 3 2 A 06 14  
8
9
10  
Mounting  
Inserts  
11  
Rating  
12  
Agency  
Approval  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color &  
Legend  
Series  
Actuator  
Poles  
Circuit  
Relay Trip  
Frequency  
& Delay  
Current Rating  
4,5  
1 SERIES  
8 TERMINAL  
C
3
6
Stud, 1/4-20  
Stud, M6  
A
B
Stud, 1/4-20, with 10-32 Screw Terminals on Voltage Pole  
Stud, M6, with M5 Screw Terminals on Voltage Pole  
2 ACTUATOR  
X
Handle, one per pole  
9 HANDLE COLOR & LEGEND  
1,2  
3 POLES  
Actuator Color  
White  
Black  
I-O  
A
C
F
ON-OFF  
Dual  
Legend Color  
Black  
White  
White  
White  
White  
Black  
Black  
Black  
2
3
4
5
Two  
B
D
G
J
1
2
3
4
5
6
7
8
Three  
Four  
Five  
Red  
Green  
Blue  
Yellow  
Gray  
H
K
M
P
L
N
Q
S
4 CIRCUIT  
Switch Only  
S
Orange  
R
1,2  
5 RELAY TRIP VOLTAGE COIL RATING  
10 MOUNTING INSERTS  
6-32 Thread  
0
Without Relay Trip Voltage Coil  
A
B
M3 Thread  
A
B
C
D
12 VDC  
24 VDC  
32 VDC  
48 VDC  
11 MAX. APPLICATION RATING  
06 600VDC  
6 FREQUENCY & DELAY  
03 DC Switch Only  
12 AGENCY APPROVAL  
A
Without Approvals  
UL489B Listed  
14  
1,3  
7 CURRENT RATING (AMPERES)  
Notes:  
1
2 Pole Unit is required for ratings between 50A - 100A.  
4 Pole Unit is required for ratings between 110A - 175A.  
2-Pole Section  
2
A Relay Trip Voltage Coil Pole may be added to either the 2 or 4 Pole construction.  
The addition of this extra pole dictates a change in the designation for the number of  
poles in selection 3.  
For Current Ratings between 50A - 100A select current code 810 (100A).  
For Current Ratings between 101A - 175A select current code 917 (175A).  
Voltage Pole must have screw terminals.  
Switch Pole must have stud terminals.  
On 3 Pole Unit, Voltage Pole to be located at P1 as standard.  
On 5 Pole Unit, Voltage Pole to be located at P3 as standard.  
810  
50A - 100A  
4-Pole Section  
917 110A - 175A  
3
4
5
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
CX-Series Circuit Breaker - UL1077 – Ordering Scheme |  
7
C X 1 B 0 14 620 2 2 A 10 C  
8
9
10  
Mounting  
Inserts  
11  
Rating  
12  
Agency  
Approval  
1
2
3
4
5
6
7
Terminal  
Actuator  
Color &  
Legend  
Series  
Actuator  
Poles  
Circuit  
Aux/Alarm  
Switch  
Frequency  
& Delay  
Current Rating  
8
1 SERIES  
8 TERMINAL  
C
2
3
5
6
Screw, 10-32  
Stud, 1/4-20  
Screw, M5  
Stud, M6  
2 ACTUATOR  
X
Handle, one per pole  
9 ACTUATOR COLOR & LEGEND  
7
3 POLES  
Actuator Color  
White  
Black  
I-O  
A
C
F
ON-OFF  
Dual  
Legend Color  
Black  
White  
White  
White  
White  
Black  
Black  
Black  
1
2
3
4
One  
Two  
Three  
Four  
B
D
G
J
1
2
3
4
5
6
7
8
Red  
10  
Green  
Blue  
Yellow  
Gray  
H
K
M
P
L
N
Q
S
4 CIRCUIT  
1, 9  
)
(
Switch Only no coil  
Series Trip current  
Relay Trip voltage  
A
B
G
Orange  
R
(
(
)
1, 2, 3, 9  
)
10 MOUNTING INSERTS  
A
B
6-32 Thread  
M3 Thread  
5 AUXILIARY SWITCH  
Without Aux Switch  
0
11 MAX. APPLICATION RATING  
6 FREQUENCY & DELAY  
10  
11  
14  
06  
300VDC  
03  
10  
11  
12  
14  
16  
DC 50/60Hz, Switch Only  
4
440 VDC without factory installed terminal bus  
440VDC with factory installed terminal bus  
600VDC  
DC Instantaneous  
DC Ultra Short  
DC Short  
DC Medium  
DC Long  
4
5
12 AGENCY APPROVAL  
A
C
Without Approvals  
UL 1077 Recognized  
6
7 CURRENT RATING (AMPERES)  
CODE AMPERES  
9
Wꢀ  
ULꢀ1077ꢀRecognizedꢀ&ꢀTUVꢀCertifiedꢀIEC/ꢀENꢀ60947-2  
220 0.200  
225 0.250  
230 0.300  
235 0.350  
240 0.400  
245 0.450  
250 0.500  
255 0.550  
260 0.600  
265 0.650  
270 0.700  
275 0.750  
280 0.800  
285 0.850  
290 0.900  
295 0.950  
410 1.000  
512 1.250  
415 1.500  
517 1.750  
420 2.000  
522 2.250  
425 2.500  
527 2.750  
430 3.000  
435 3.500  
440 4.000  
445 4.500  
450 5.000  
455 5.500  
460 6.000  
465 6.500  
470 7.000  
475 7.500  
480 8.000  
485 8.500  
490 9.000  
495 9.500  
610 10.000  
710 10.500  
611 11.000  
711 11.500  
612 12.000  
712 12.500  
613 13.000  
614 14.000  
615 15.000  
616 16.000  
617 17.000  
618 18.000  
620 20.000  
622 22.000  
624 24.000  
625 25.000  
630 30.000  
635 35.000  
640 40.000  
650 50.000  
660 60.000  
665 65.000  
670 70.000  
675 75.000  
680 80.000  
685 85.000  
690 90.000  
695 95.000  
810 100.000  
911 115.000  
912 125.000  
Notes:  
1
Only available when tied to a protected pole  
Requires special P/N consult factory for details  
2
3
4
Voltage trip circuit coil not rated for continuous duty - use instantaneous delay code 10  
Contacts Rated for 20A @ 80 VDC  
440VDCꢀRatingꢀavailableꢀinꢀtwoꢀdifferentꢀwiringꢀconfigurations.ꢀ  
(see next page for more details)  
600 VDC only available with factory installed terminal bus (see next page for more details)  
Single pole units available up to 125A, multi pole units limited to 115A Max.  
(see next page for more details)  
3 Pole units must include one Auxiliary switch pole (circuit code A or G) - Requires Special  
Part Number. (see next page for more details)  
Screw Terminals are limited to 50A max.  
5
6
7
8
9
Agency approval code W only available with 440 VDC rating & circuit code B.  
10 4 Pole 600 VDC units only available up to 75A Max. (see next page for more details)  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
8
CX-Series Circuit Breaker - Handle UL489 Listed – Ordering Scheme  
Dimensional Specifications: in. [mm]  
2.259+0.020  
[57.38+0.50]  
0.265  
[6.73]  
0.502  
[12.75]  
0.755  
0.579  
[14.72]  
[19.18]  
MAXIMUM  
1.719  
[43.66]  
0.380  
[9.65]  
1.843+0.020  
[46.81+0.50]  
+0.050  
–0.020  
+1.27  
–0.50  
3.094  
78.59  
2.062+0.020  
[52.37+0.50]  
30.0º  
1.052  
[26.72]  
0.124  
[3.16]  
0.626+0.020  
[15.90+0.50]  
2.264+0.020  
[57.51+0.50]  
SHOWN WITH STUD  
TERMINAL CONFIGURATION  
1.017  
[25.82]  
1.515  
[38.48]  
MAXIMUM  
3.672  
[93.268]  
2.259  
[57.38]  
&
(205/410 VDC)  
2.736  
SHOWN WITH SCREW  
TERMINAL CONFIGURATION  
[69.49]  
0.744  
[18.90]  
(WITH SCREW TERMINAL)  
2.946  
1.520  
[38.61]  
[74.83]  
(WITH STUD TERMINAL)  
0.760  
[19.30]  
0.078 TYP  
[1.98]  
3.276  
[83.21]  
(UNFOLDED BARRIER)  
REW TERMINAL)  
2.946  
1.520  
[38.61]  
[74.83]  
UD TERMINAL)  
3.276  
[83.21]  
0.760  
[19.30]  
0.078 TYP  
[1.98]  
FOLDED BARRIER)  
1.062  
[26.97]  
TOLERANCES +.005[.12]  
2.062  
[52.37]  
0.750 TYP  
[19.05]  
0.625  
[15.88]  
CX1  
CX2  
Notes:  
1
2
All dimensions are in inches [millimeters].  
Toleranceꢀ±.020ꢀ[.51]ꢀunlessꢀotherwiseꢀspecified.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
CX-Series Circuit Breaker - UL489B – Dimensional Specifications |  
9
Dimensional Specifications: in. [mm]  
OPTIONAL VOLTAGE POLE  
SEE NOTE 1  
POLE 1  
CX3  
POLE 2  
POLE 3  
CX2  
CX3 - 2 POLE SWITCH (CX2)SHOWN  
WITH OPTIONAL VOLTAGE POLE  
50A-100A DEVICE, 600VDC  
POLE 1  
OPTIONAL VOLTAGE POLE  
SEE NOTE 2  
POLE 2  
POLE 3  
SEE NOTE 3  
POLE 4  
POLE 5  
CX5 - 4 POLE SWITCH (CX4)SHOWN  
WITH OPTIONAL VOLTAGE POLE  
101A-175A DEVICE, 600VDC  
Notes:  
1
2
3
4
All dimensions are in inches [millimeters].  
3ꢀpoleꢀconfigurationꢀsuppliedꢀwithꢀvoltageꢀcoilꢀonꢀpoleꢀ1.ꢀOptionalꢀlocationꢀpoleꢀ3.ꢀConsultꢀfactory.  
5ꢀpoleꢀꢀconfigurationꢀsuppliedꢀwithꢀvoltageꢀcoilꢀinꢀcenterꢀpole.ꢀ(Poleꢀ3)  
Line & Load connections requires bus connection as shown.  
2
2
Minimum cross selection .127 in (81.94 mm )  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
10  
CX-Series Circuit Breaker - UL1077 – Dimensional Specifications  
Dimensional Specifications: in. [mm]  
Notes:  
1
2
All dimensions are in inches [millimeters].  
600V Rating requires minimum of 2 protected poles  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
Sales Representatives, Distributors & Company Profile |  
11  
Authorized Sales Representatives and Distributors  
Click on a region of the map below to find your local representatives and distributors or visit  
www.carlingtech.com/findarep.  
CANADA  
EUROPE  
USA  
MIDDLE  
EAST  
MEXICO  
AFRICA  
ASIA-PACIFIC  
OCEANIA  
SOUTH  
AMERICA  
About Carling  
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches  
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power  
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,  
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical  
components, they engineer powerful solutions! To learn more about Carling please visit  
www.carlingtech.com/company-profile.  
To view all of Carling’s environmental, quality, health & safety certifications please visit  
www.carlingtech.com/environmental-certifications  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
Worldwide Headquarters  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Phone: 860.793.9281 Fax: 860.793.9231  
@
Email: sales carlingtech.com  
@
Northern Region Sales Office: nrsm carlingtech.com  
@
Southeast Region Sales Office: sersm carlingtech.com  
@
Midwest Region Sales Office: mrsm carlingtech.com  
@
West Region Sales Office: wrsm carlingtech.com  
@
Latin America Sales Office: larsm carlingtech.com  
Asia-Pacific Headquarters  
Carling Technologies, Asia-Pacific Ltd.,  
Suite 1607, 16/F Tower 2, The Gateway,  
Harbour City, 25 Canton Road,  
Tsimshatsui, Kowloon, Hong Kong  
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332  
@
Email: sales carlingtech.com.hk  
@
Shenzhen, China: shenzhen carlingtech.com  
@
Shanghai, China: shanghai carlingtech.com  
@
Pune, India: india carlingtech.com  
@
Kaohsiung, Taiwan: taiwan carlingtech.com  
@
Yokohama, Japan: japan carlingtech.com  
|
|
Europe Middle East Africa Headquarters  
Carling Technologies LTD  
4 Airport Business Park, Exeter Airport,  
Clyst Honiton, Exeter, Devon, EX5 2UL, UK  
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477  
@
Email: ltd.sales carlingtech.com  
@
Germany: gmbh carlingtech.com  
@
France: sas carlingtech.com  
www.carlingtech.com  
REV_03_2017  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY